PAT Hirschmann Wika Angle Sensor Replacement
- on September 17, 2024
- Categories: News
PAT Hirschmann Wika Angle Sensor (064-090-061-451) is a direct replacement for (064-103-060-007) and (064-143-060-005) angle sensors
Crane Angle Sensor Installation Instructions (SAMPLE)
- Remove cover from PAT Hirschmann Cable Reel
- Disconnect the JST angle sensor connector from the X4 terminal.
- Remove current angle sensor assembly, mounting plate, and JST angle sensor connector from the cable reel housing
- Install new angle sensor 064-090-061-451 in place of previously removed angle sensor.
- Do not reinstall board on new angle sensor mounting plate.
- Route JST connector assembly around the length potentiometer and reconnect to the X4 terminal.
- Use the adjustment screws to ensure the top of the angle sensor plate is parallel with the boom. (if necessary, readjust angle sensor until the angle displayed on console reads 0°)
- Reinstall cover on Cable Reel.
NOTICE
The information in this document is subject to change without notice. BTS Crane Parts Inc makes no warranty of any kind with regard to this material, including, but not limited to the implied warranties of merchantability and fitness for a particular purpose. BTS Crane Parts Inc shall not be liable for errors contained in this manual or for incidental or consequential damages in connection with the furnishing, performance, or use of this manual.